{"product_id":"proactive-protekt-aire-7000-lateral-rotation-low-air-loss-alternating-pressure-and-pulsation-mattress-system","title":"Proactive Protekt Aire 7000 Lateral Rotation\/Low Air Loss\/Alternating Pressure and Pulsation Mattress System","description":"\u003ch2 style=\"text-align: center;\"\u003eProactive Protekt Aire 7000 Lateral Rotation\/Low Air Loss\/Alternating Pressure and Pulsation Mattress System\u003c\/h2\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eReduces Pressure\u003c\/h4\u003e\n\u003cblockquote\u003e\n\u003cp\u003eThe Protekt Aire 7000 combines lateral rotation, low air loss, alternating pressure and pulsation into one integrated mattress system. It is designed to improve skin protection and comfort, simplify patient repositioning, and provide clear safety features and alarms for clinical use.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch4\u003eBenefits\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eReduce pressure-related skin breakdown by providing continuous pressure redistribution without constant manual turning.\u003c\/li\u003e\n\u003cli\u003eImprove skin microclimate and reduce moisture buildup with independent low air loss, helping skin stay drier and cooler.\u003c\/li\u003e\n\u003cli\u003eMake transfers and bed exits easier and safer with a static mode and auto-firm setup that stabilizes the surface quickly.\u003c\/li\u003e\n\u003cli\u003eSave caregiver time and effort by using automated turning modes and programmable cycle times instead of manual repositioning.\u003c\/li\u003e\n\u003cli\u003eIncrease patient comfort through alternating and pulsation options that create a more restful support surface.\u003c\/li\u003e\n\u003cli\u003eEnhance safety with audible\/visual alarms, an auto-lockout control panel, and a two-stage fowler detector that prevents “bottoming out.”\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLateral rotation with three turn modes: Left Turn, Right Turn and Full Turn; adjustable angles and cycle times from 10 to 95 minutes.\u003c\/li\u003e\n\u003cli\u003eTrueCare alternating technology that re-inflates the first set of cells before the second set deflates for smoother transitions and improved comfort.\u003c\/li\u003e\n\u003cli\u003eiLAL (independent Low Air Loss) that periodically delivers high-volume air loss to reduce moisture and skin heat at the support surface.\u003c\/li\u003e\n\u003cli\u003eSelectable alternating cycle times (10, 15, 20, 25, 30 minutes) plus a static mode for safe patient transfers; LED display for monitoring settings.\u003c\/li\u003e\n\u003cli\u003eConstant Low Pressure (CLP) mode for a low-pressure static surface when a dynamic surface is not tolerated but pressure redistribution is required.\u003c\/li\u003e\n\u003cli\u003ePulsate mode that provides a periodic pressure-changing static surface with adjustable cycle time.\u003c\/li\u003e\n\u003cli\u003e18 bladder cell-on-cell mattress construction to help prevent bottoming out if power is lost.\u003c\/li\u003e\n\u003cli\u003eAuto-firm mode for quick setup and easier ingress\/egress from the bed.\u003c\/li\u003e\n\u003cli\u003eAudio and visual alarms for power failure, low pressure and service issues with error codes for troubleshooting.\u003c\/li\u003e\n\u003cli\u003eNylon quilted top cover that is fluid-resistant, antimicrobial\/antibacterial, vapor-permeable and fire retardant.\u003c\/li\u003e\n\u003cli\u003eTwo-stage fowler detector: automatically stops turning at 20° and increases pressure output at 45° to prevent bottoming out.\u003c\/li\u003e\n\u003cli\u003eAuto-lockout on the control panel to prevent accidental changes to settings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eOperating modes: Lateral rotation, Low air loss, Alternating pressure, Pulsation, Static (CLP).\u003c\/li\u003e\n\u003cli\u003eTurn cycle time range: 10–95 minutes (adjustable).\u003c\/li\u003e\n\u003cli\u003eAlternating cycle time options: 10, 15, 20, 25, 30 minutes.\u003c\/li\u003e\n\u003cli\u003eMattress cell design: 18 bladder cell-on-cell configuration.\u003c\/li\u003e\n\u003cli\u003eTurn modes: Left Turn, Right Turn, Full Turn.\u003c\/li\u003e\n\u003cli\u003eCover material: Nylon quilted top — fluid-resistant, antimicrobial\/antibacterial, vapor-permeable, fire retardant.\u003c\/li\u003e\n\u003cli\u003eDisplay: LED for cycle selection and status.\u003c\/li\u003e\n\u003cli\u003eAlarms: Audio\/visual for power failure, low pressure and service with error codes.\u003c\/li\u003e\n\u003cli\u003eFowler detector behavior: stops turning at 20°; increases pressure output at 45°.\u003c\/li\u003e\n\u003cli\u003eControls: Auto-firm mode and auto-lockout for safety.\u003c\/li\u003e\n\u003cli\u003eSpecial technologies: TrueCare alternating re-inflation sequence; iLAL independent low air loss.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/lifeinspiringsolutions.com\/pages\/proactive-medical-warranty-refund-policies\"\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0782\/3307\/5896\/files\/ProactiveMedical_Warrenty_Return_Button_2_00001.jpg?v=1765056410\"\u003e\u003c\/a\u003eIf you have questions about this item please call a Life Inspiring Solutions Expert at \u003cstrong\u003e1-888-877-8764.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Proactive Medical","offers":[{"title":"36” x 80” x 8”","offer_id":52209005625528,"sku":"PRO-80070","price":4100.0,"currency_code":"USD","in_stock":true},{"title":"42 ”x 80” x 8”","offer_id":52209005658296,"sku":"PRO-80070-42","price":4400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0782\/3307\/5896\/files\/Protekt_Aire_7000_80070.jpg?v=1761465648","url":"https:\/\/lifeinspiringsolutions.com\/products\/proactive-protekt-aire-7000-lateral-rotation-low-air-loss-alternating-pressure-and-pulsation-mattress-system","provider":"Life Inspiring Solutions","version":"1.0","type":"link"}